Bathroom mould removal with inspection

Bathroom mould removal with inspection and report

Extensive mould removal from a bathroom with a popcorn ceiling. Why would they use this type of finish is beyond me. Developed in the 70’s for what reason I don’t know. I needed to use 3 x the chemical and use a different method to apply. In the end was success.

PRE-INSPECTION:
Mould growth to ceiling walls and window surrounds caused by condensation and lack of ventilation. Current exhaust fan is inadequate.

TREATMENT:
Anti-microbial treatment to all affected areas.

OWNER RECOMMENDATIONS:
– Upgrade existing exhaust fan to a model that extracts a min of 450m3 of air per hour.
– Paint ceiling and walls using a mould inhibitor additive or wet area paint. Min two coats.
– Due to the distance from the shower recess to the window exhaust fan which is approx 10 meters, add a outdoor sealed motor fan to push the humid air to the exhaust fan.
– Leave exhaust fan running for additional 20 mins after use particularly during the winter months.

CONCLUSION:
This is a hard fix situation, however if recommendations are followed there should be less chance of condensation and mould growth in the future.

© copyright 2022 mistermould.com.au